Hot side of any 120V outlet on the generator — one leg only
Orange, 18 AWG
AC SENSE N
Neutral side of the same outlet
White/Orange, 18 AWG
Settings — GenStart Web Page
Setting
Value for the GP9200E
Why
Start Mode
Button
The GP9200E starts from a panel push-button, not a key switch or starter solenoid wire
Double-Press Gap
3 seconds
This generator's start module needs two presses: the first wakes it, the second cranks
Press Length (Start)
1 second
Matches a firm press-and-release
Press Length (Stop)
1 second
A single press shuts the engine down
Start Confirm Time
15 seconds
AC power must appear within this window or the attempt counts as failed
Retries / Retry Delay
3 / 10 seconds
Automatic re-try; after 3 failures GenStart stops and reports a fault
⚠ CHECK YOUR PANEL FIRST: Generac has shipped GP-series units with two different start modules. Before you rely on unattended operation, stand at the generator and start it by hand with the button: if one press starts it, turn Double-Press OFF in the GenStart settings. If it takes two presses (first press lights the panel, second press cranks), leave Double-Press ON at 3 seconds. Use GenStart's Test Run button to confirm before leaving the system unattended.
TAP IN PARALLEL: The two START/STOP wires splice alongside the existing push-button wires (posi-taps or solder and heat-shrink). Nothing is cut, so the panel button still works normally. NO OTHER CHANGES: Choke, ignition, and fuel systems stay factory — nothing to modify. WHY THE AC SENSE WIRES MATTER: They are how GenStart knows the engine actually started. Without them it cannot verify a start or retry a failed one. CO-SENSE: If the generator shuts down for carbon monoxide, clear the fault at the generator before auto-start will work again. Never bypass the CO system. SAFETY: Disconnect the generator battery before you begin wiring. Never work on the 120V outlet while the generator can start.